- Detailed Results: renamed "Hourly graphs" to "custom graphs" for more clarity
- Performance: running the simulation in subhourly steps is now faster
- Shadings: the calculation of the shading factors table is now faster, especially for projects with a ground object
- Shadings: shading factor tables computed with a different PVsyst version are now reported in the Near Shadings dialog and recomputed after user confirmation, or automatically during batch and optimization runs
- Weather data: sub-hourly data import is now supported for PVsyst standard format weather files.
- 3D scene: fixed issue with the module count per orientation for system definitions with mixed orientations
- 3D scene: fixed small issues related to the PVC2 import
- Optimizers: fixed issue with energy balance errors when clipping occurs at the optimizer level, which could affect results in some systems
- Optimizers, Huawei: setting new strings to inverters no longer causes crashes
- Output file: fixed issue preventing output files from being generated at the end of some simulations
- Pumping: fixed a conversion error for the foot of water column head unit
- Pumping: pre-sizing of the suggested pump and PV powers now accounts for the feeding altitude. This fixes underestimated suggested powers and incorrect oversized-pump warnings when the well static depth is small compared to the total head
- Pumping, lake or river to storage: calculation of the head level now accounts for the tank level. This affects the simulation results and the choice of pump
- Report: default values for energy units and number of decimals in the loss diagram are now stored and managed through the report options
- Report: the battery remaining lifetime is available again
- Results: fixed issue in converter losses energy balance check, where CL_Pmin (converter losses due to power threshold) was erroneously accounted as a balance error. This did not affect simulation results
- Shadings: improved accuracy of linear shadings, electrical shadings and module layout shading calculations (*)
- Transformer losses: parameters for MV transformers defined per sub-array are now correctly saved
- Transposition model: POA retro-transposition now yields realistic GHI values at low grazing angles, where several solutions, or none, may exist (*).