Loxone Config provides ready-to-install smart home functionality with one-click auto configuration standards. No other home automation software does the work for you like this, let alone for free. Just click and drag components – no coding and no complex programming required. Auto Configuration Program basic functions like lighting or music all together in one click, all according to Loxone Standards & Recommendations. You also get full visualization with our free app for smartphones or tablets. From there, specific needs for customers can become implemented in hours – not days. Simulation & Live View Before going live, you can fully test the configuration in Simulation Mode and preview how functions will deliver according to your project specifications. In Live View you can see how the building operates remotely. No need to go on-site, you’ll always be able to check how the system is running no matter where you are. Project Planning Get ready for project planning and proposals to be created faster and easier than ever before. Helpful tools such as the ability to search and replace items makes it simple to navigate the best product selection for your project. Project Analysis Think “Spell Check” for your configuration. The Project Analysis feature reliably reviews your configuration as well as key points such as your password strength, unused objects or light circles, convertible objects and even offers help with statistics and data. Finish each configuration knowing you had a second set of eyes on your work! Multiplicator The Loxone Multiplicator allows you to manage several Miniservers under one umbrella. For example, if a hotel has 30 rooms, each room has its own its own Miniserver, they can all be programmed and managed together under one project file – a multiplier file. You can create a multiplier file by selecting the project type or converting an existing project. Free updates Our software improves with every update. We continuously test and expand our software based on market feedback. We’re always exploring new features and functionality for all Loxone homes and buildings to come.

winget install --id Loxone.LoxoneConfig --exact --source winget

Latest 17.3·November 23, 2026

Release Notes

New Security

  • Multi-Factor Authentication now supports authenticator apps (TOTP) in addition to codes sent by email.
    • Users can add an authenticator app, such as Google or Microsoft Authenticator, in LOXONE Config under Authentication by scanning a QR code. Users without a usable email address set it up at their first login.
    • The login requests the code of the user’s default method and offers the other methods.
    • The new project setting “Multi-Factor Methods” defines which methods users may use; new and existing projects allow email and authenticator app.
    • Authenticator codes require the correct time on both the Miniserver and the device running the app. LOXONE Config indicates when the Miniserver’s clock is incorrect.
    • After 30 incorrect authenticator codes, the user’s authenticator app is blocked for 24 hours; an administrator can release it in “Logins & Firewall”.
    • Administrators can view and delete a user’s methods in the user’s Authentication setting. Without a connection, the methods saved in the project are shown.
    • Trust: Trust users set up the authenticator app at their Trust source and can use it on every Trust member.
    • Gateway/Client: Miniserver Gen. 2 Clients verify authenticator codes via their Gateway.
    • Authentication methods are stored encrypted on the Miniserver.
  • The Logins dialog, now “Logins & Firewall”, shows which clients the application firewall of each Miniserver blocks or slows down, and can release blocks and a Remote Connect lockdown.
  • AD5-T637: The application firewall now informs apps and browsers how long a block, lockdown or rate limit lasts (Retry-After). General
  • System Status now shows the day of a planned Miniserver update; postponing moves it by a fixed number of days. Fixed Security
  • Statistics are now only available for functions the user has access to.
  • Hardened the Miniserver login against password guessing.
  • Hardened LAN Intercommunication.
  • Hardened the network device interface.
  • Hardened Miniserver web service permissions.
  • Hardened the Caller key press callback.
  • Hardened file transfer between LOXONE Config and the Miniserver.
  • Changing block parameters via the App now requires the expert mode right.
  • Hardened Gateway/Client communication.
  • Hardened the HTTPS client.
  • Configuration access over the Internet can now only be allowed from the local network.
  • Hardened Gateway communication.
  • A web command with “./” before its address and a file extension no longer bypasses the login check.
  • Hardened the LOXONE Config connection and the web server.
  • Hardened Miniserver network services and the login.
  • Hardened the Pico C interpreter.
  • Failed logins and blocks via Remote Connect now apply to the client’s address instead of to all Remote Connect access. Access
  • A user without a password no longer triggers an insecure password warning. Audio
  • Security improvements. Config
  • The message indicating that someone is already connected now shows the IP address of a Remote Connect client. Devices
  • Live Learning: The Modbus Extension is now shown with its image, and the correct extension type is created.
  • Wall Display:
    • Hardened the service interface: test and service functions require Miniserver credentials, the interface is open for only 30 minutes after startup before pairing, and repeated failed logins lead to a lockout.
    • Hardened the firmware update, the offline update upload and the Miniserver certificate check.
    • Crash reports no longer contain the serial number, and at most 5 per day are uploaded.
    • Offline update packages and screenshots no longer remain on the device. Diagnostics
  • The def.log now records who restarted, rebooted or updated the Miniserver. Energy
  • Wallbox: VID and ED are now reset reliably after the vehicle is disconnected. Gateway/Client
  • The device status web services of a Client Miniserver work again for users with Multi-Factor Authentication. General
  • Energy meters of type Wallbox now use the Inverted wiring type by default.
  • BG-I54995: The Alarm Clock now shows the correct time for the next alarm.
  • Fixed an issue where the API connection was only possible from NFC to Wallbox.
  • BG-I55706: The Sequence Controller indents the lines between if and endif again instead of removing their indentation. Lighting
  • BG-I55804: Automatic Designer rules setting the Push-button Dimmer to a value work again; value commands with the “/force” suffix were previously rejected. Miniserver
  • The login code email of an unregistered Miniserver now reports that the Miniserver is not registered.
  • If a login code email could not be sent, the next login no longer responds with “code already sent”.
  • Trust now reaches a member via its local address even when the address contains the HTTP port. Plugins
  • BG-I55429: Husqvarna (1.1.3):
    • Fixed: The Miniserver no longer stops the plugin for excessive CPU load after the connection to the Husqvarna cloud closes.
    • Fixed: The plugin now reconnects after the connection to the Husqvarna cloud drops instead of keeping stale mower states.
    • Improved: Translations have been updated.
  • LOXONE plugins such as Exosphere are no longer warned about or stopped for exceeding resource limits.
  • The plugin resource message no longer shows memory values that appear as thousands of MB. Setup
  • The Miniserver search no longer requests Windows Firewall permission after installation. Stability
  • The Miniserver no longer crashes in the BACnet service while values change.
  • The Miniserver no longer hangs at program start when a tablet references an invalid user.
  • The Miniserver no longer restarts when reading the network configuration takes too long.
  • The Miniserver no longer crashes on every program start after unpaired tablets are removed.
  • Miniserver Gen. 1 no longer restarts or crashes when sending emails via the LOXONE mail service.
  • Config no longer crashes when a Client is added to a standalone Miniserver.
  • A Trust member of a Gen. 1 Miniserver no longer randomly shows the Miniserver Go icon.
  • BG-I48809: App connections that no longer respond are now closed after 5 minutes and no longer use up connection slots. Touch Pure Display
  • C7WT-I241: The Wallbox control now shows the plug-in time and managed mode.
  • C7WT-I242: The Touch Pure Display send interval is now set in seconds.
  • C7WT-I226: The Intelligent Room Controller now indicates when heating or cooling is unavailable.
  • Roof Window Shading and Gate Controller now display arrow badges.
  • The target temperature is now shown immediately after leaving Eco mode.
  • BG-I55541: The Touch Pure Display now requests live Wallbox values. Trust
  • BG-I28413: After the Trust Manager Miniserver is replaced, loading the Miniserver’s changes no longer restores the old serial number of the Trust Manager.
  • BG-I28413: The serial number of a Trust member can again be set to the serial number of the project’s Miniserver.
  • Two vehicles can no longer have the same hardware ID.
  • Vehicles deleted on the Trust source are now also deleted on the Trust members.

Installer type: zip

x86—19D04156046B466191BB6FBA54B90BAFE34678BC3CF02076875D162D88DD3FEC

Details

Homepage
https://www.loxone.com/enus/products/loxone-config/
License
Proprietary
Publisher
Loxone Electronics GmbH
Support
https://www.loxone.com/enus/support/
Privacy Policy
https://www.loxone.com/enus/info/data-protection-statement/
Copyright
© 2009 - 2026 Loxone Electronics GmbH

Older versions (5)

17.2
x86—320AB58E10C6C9E4B60C6B874519C08834CBE198339B9CD0AB08A94AF42C654E
17.1
x86—478B163C6883514D9FAF83E4CE2FC1D4637BD0C5B3B8D05600B4EEADE475949A
17.0
x86—7A254CF4E9909DC865152C9D76CD92ABD633E7C73F7F2906D64363E5B05BCC76
16.1
x86—5A41E9795C3668FC8D414A66D1916D9C2B277A4CB7FC3AD6D9D2F93B223885AE
16.0
x86—F7D04FDF24BE50BD3711A9B214F2E025CEC51487CE826BEC89EA49455EE1FEE5